Selected Publications
2008
"A handheld computer as part of a portable in vivo knee joint load monitoring system", ASME, Journal of Medical Devices, vol. 2-3, issue September, 09/2008.
,
"Sensate scaffolds coupled to telemetry can monitor in vivo loading from within a joint over extended periods of time.", J Biomed Mater Res B Appl Biomater, vol. 84, issue 1, pp. 263-70, 2008 Jan.
PMCID: PMC2367210 PMID: 17557310 ,
2007
"Selective cell proliferation can be controlled with CPC particle coatings.", J Biomed Mater Res A, vol. 81, issue 4, pp. 939-47, 2007 Jun 15.
PMCID: PMC2288747 PMID: 17252549 ,
"Sensate scaffolds can reliably detect joint loading.", J Biomed Mater Res B Appl Biomater, vol. 81, issue 1, pp. 30-9, 2007 Apr.
PMCID: PMC2396224 PMID: 16941586 ,
2006
"An instrumented scaffold can monitor loading in the knee joint.", J Biomed Mater Res B Appl Biomater, vol. 79, issue 2, pp. 218-28, 2006 Nov.
PMCID: PMC2288746 PMID: 16637034 ,
2005
"TGF-beta1-enhanced TCP-coated sensate scaffolds can detect bone bonding.", J Biomed Mater Res B Appl Biomater, vol. 73, issue 1, pp. 43-53, 2005 Apr.
PMCID: PMC2288753 PMID: 15682399 ,
"In vivo strain measurements from hardware and lamina during spine fusion.", J Biomed Mater Res B Appl Biomater, vol. 75, issue 2, pp. 243-50, 2005 Nov.
PMID: 16161111 ,
2004
"Transforming growth factor-beta1 accelerates bone bonding to a blended calcium phosphate ceramic coating: a dose-response study.", J Biomed Mater Res A, vol. 68, issue 3, pp. 537-43, 2004 Mar 01.
PMID: 14762934 ,
2003
"Evaluation of a new CPC-to-gauge bonding technique with the use of in vitro fluid flow.", J Biomed Mater Res B Appl Biomater, vol. 66, issue 2, pp. 514-9, 2003 Aug 15.
PMID: 12861601 ,
2001
"Strain transfer between a CPC coated strain gauge and cortical bone during bending.", J Biomed Mater Res, vol. 58, issue 2, pp. 147-55, 2001.
PMID: 11241333 ,
"Long-term measurement of bone strain in vivo: the rat tibia.", J Biomed Mater Res, vol. 58, issue 3, pp. 277-81, 2001 May 01.
PMID: 11319741 ,
"Surface enhancements accelerate bone bonding to CPC-coated strain gauges.", J Biomed Mater Res, vol. 56, issue 1, pp. 109-19, 2001 Jul.
PMID: 11309797 ,
2000
"A comparison of in vitro and in vivo degradation of two CPC strain gauge coatings.", J Biomed Mater Res, vol. 53, issue 3, pp. 211-5, 2000.
PMID: 10813759 ,
1999
"Bone bonding strength of calcium phosphate ceramic coated strain gauges.", J Biomed Mater Res, vol. 48, issue 1, pp. 32-5, 1999 Spring.
PMID: 10029147 ,
1998
"Interface strength studies of calcium phosphate ceramic coated strain gauges.", J Biomed Mater Res, vol. 43, issue 4, pp. 462-8, 1998 Winter.
PMID: 9855205 ,
"A mechanical and histomorphometric analysis of bone bonding by hydroxyapatite-coated strain gages.", J Invest Surg, vol. 11, issue 1, pp. 29-48, 1998 Jan-Feb.
PMID: 9659635 ,
1997
"In vivo strain measurements collected using calcium phosphate ceramic-bonded strain gauges.", J Invest Surg, vol. 10, issue 5, pp. 263-73, 1997 Sep-Oct.
PMID: 9361990 ,
1996
"Evaluation of factors affecting bonding rate of calcium phosphate ceramic coatings for in vivo strain gauge attachment.", J Biomed Mater Res, vol. 33, issue 3, pp. 121-32, 1996 Fall.
PMID: 8864883 ,
"Bilateral symmetry of biomechanical properties in rat femora.", J Biomed Mater Res, vol. 32, issue 2, pp. 285-8, 1996 Oct.
PMID: 8884507 ,
1995
"Technical note: development of a model for study of in vivo bone strains in normal and microgravity environments.", J Appl Biomater, vol. 6, issue 3, pp. 203-8, 1995 Fall.
PMID: 7492812 ,